Sensidyne Industrial Health and Safety

Gilian Go-Cal Pro Calibrator

NEW! The Next Generation of Air Flow Calibrators

Gilian Go-Cal Pro Calibrator

The Only Portable Air Flow Calibrator with +/- 1% Accuracy across Entire 3 Flow Ranges.   

Calibrate air sampling pumps to set & verify flow rates with complete confidence - anywhere you work. Lightweight and easy to operate, the Gilian® Go-Cal™ Pro is the must-have precision flow meter for OEHS professionals.

ACCURACY
•  +/- 1% Accuracy across the Entire Range of Flow Rates in 3 Instruments:

    » Low Flow:  5-600 cc/min

   
    » Standard Flow:  600-5000 cc/min

   
    » High Flow:  4-30 LPM

    

•  Provides % deviation to show flow stability 
•  Engineered with mass flow differential pressure technology, is NIST traceable, and certified within our ISO 17025 laboratory

PORTABILITY
•  Small, lightweight, durable design, and no moving parts
•  Hand held ergonomic design makes it easier to hold and perform data entry
•  Charges with a standard USB-C cable

EASY TO USE
•  Easy to setup (just connect tubing and start pump)
•  Fast stabilization – gives instantaneous reading
•  Large Color Touch Screen Display
•  Averages flow over user selected time
•  Customization of local languages and preferred units of measure
•  Bluetooth® Communications Options (coming soon)

SAMPLING INTEGRITY
•  Creates digital traceability which ties sampling chain together
•  Flow Verification Event Storage
•  Flow Meter report provides event information and information about the flow meter being utilized (i.e. serial number, date of last calibration)

ADVANCED CALIBRATION TECHNOLOGIES
•  Ability to select Sample Periods
•  The user may select a specific sample time to be averaged
•  Internal sensors standardize flow rates using reference temperatures and pressures (STP)
•  STP-corrected flow rates facilitate data comparison across different environmental conditions, eliminating the need for external calculations
•  Users can set corrected temperature and pressure values according to various standards
•  On board computing can data log the calibration events and perform statistical analysis on the deviations between readings
•  Users can define statistical parameters for percent deviation over the sample period
•  Improved user interface capabilities with full touch screen keyboards for completing data input, and user defined fields for maintaining sample integrity
•  Displayed date of last calibration, serial numbers, and reminders for next calibration due dat
•  Calibrators can generate printable calibration reports that include sample information, saved instrument settings, and sample flow rate results


Honored in Occupational Health & Safety's 15th annual
New Product of the Year awards — HERE

 

Contact our team of IH experts to inquire further:

» SEND INQUIRY

 

 

 

    

Specifications

 

Flow Ranges

Low:  5 to 600 cc/min

 

Standard:  600 to 5,000 cc/min

 

High:  4,000 to 30,000 cc/min

 

(Volumetric and STP flow averaging available)

Accuracy

±1% of reading or 2 cc/min, whichever is greater at standard conditions (21.1OC and 101.3kPa)

Environmental Sensors

Ambient Temperature and Pressure present in flow stream

Averaging Function

User selectable sample sampling time in seconds. Four pre-sets and user defined (5 – 5,000 sec.)

Gas Compatibility

Non-corrosive, Non-condensing

Flow Direction

Pressure and Suction

AC Charger

5 VDC

Charging Cable

USB-C to USB-A Cable

Battery

Rechargeable lithium nickel cobalt aluminum oxide (NCA) battery

Battery Charge Time

Less than 6 hours

Operation Time

Up to 24 hours*  Up to 400 calibrations on a single charge**

Operating Temperature

0 to 45OC (32 to 113OF)

Storage Temperature

-20 to 60OC (-4 to 140OF)

Operating Humidity

0 – 85% RH, non-condensing

Operating Pressure

700mbar to 1546mbar (525mmHg to 1160mmHg)

Operating Altitude

-1,000m (-3280ft) to approximately 3050m (10,000ft) above sea level

Display

Multi-color LCD capacitive touchscreen

Connectivity

USB-C to PC for Gilian Connect.  Bluetooth(R) option for Gilian Mobile (optional at time of purchase by customer)

SmartCal

SmartCal capable with GilAir Plus Communications Dock. Accessory Cables Required (not included).

Report Generation

Flow verification events are recorded and saved as viewable reports on the unit and are available for download through provided software.

External Dimensions (HxWxD)

5.0in x 3.6in x 2.0in

Tube Adapters

0.375in OD straight barbed (STD & HIGH),
0.250in OD straight barbed (LOW)

Weight

0.75lbs (0.4kg)

IP Rating

IP54

Warranty

24 months from date of purchase

Certifications/Approvals

EN 61010-1, CE, and RoHS compliant

 

Approved for shipping and transport per UN/DOT 38.3 and IEC 62133-2 (2nd Edition).

*   Running continuously with screen dimming function.

** Based on 30 second averaging and pump adjustments up to 2 minutes each, full brightness.