The new standard in Fixed Gas Detection Systems

.
 


Universal Area Monitor Accepts Combustible (Infrared or Catalytic), Toxic and Oxygen Gas Sensors.

Highest Reliability And Function
• Sensor Test-On-Demand, With On-board Gas Generator
• Predictive Sensor End-of-Life Warning
• Missing Or Non-functional Sensor Indication

Intrinsically Safe Sensor Head
• Shop Calibrate And Hot-swap Gas Sensors in Classified Areas
• Mount Sensor Up To 100 ft./30 m. Away Without XP Conduit

Intelligent SensAlert Plus Sensors
• Auto-recognition And Set-up From Sensor Memory Provides
• Operating Parameters And Diagnostics for All Plus Transmitters

International Performance Approvals
• Performance Tested and Certified To FM and ATEX Standards
• Unrestricted Hazardous Classified Area Installation and Operation

Flexible Installation or Retrofit
• 2-Wire and 3-Wire Transmitters With Enclosure Options
• Non-intrusive Configuration And Maintenance Interface
• Remote Sensor / Gassing, Duct Mount and Sample Draw
• Configurable Alarms: Fault Conditions, Gas Levels, Test-On-Demand, Predictive Sensor Failure and Time Weighted Averages

Smart Sensor Technology enables SensAlertPlus to automatically recognize and configure to the gas type and range of the sensor, using the latest calibration data. The Predictive Sensor Failure (PSF) function provides warning of approaching sensor end-of-life. Non-volatile memory stores calibration date and time, operating parameters, default settings and PSF values.

Unique Test-On-Demand (TOD) built-in gas generation cell is a Functional Sensor Test with data recall, that ensures sensors are ‘healthy’ eliminating manual bump testing.

Maintenance is greatly reduced with a non-intrusive, menu-driven user interface for functional tests and configuration (password protected). A large graphic display shows step-by step instructions for calibration, configuration and data retrieval. SensAlertPlus Sensors are shipped factory calibrated and have been Agency approved for hot-swapping in hazardous classified areas.

Performance Testing and Certification permits virtually unrestricted operation in hazardous classified areas. Intrinsically safe installation solves difficult application problems with minimal maintenance, while delivering a high level of operational security and confidence with the lowest cost of ownership.

Fully Configurable Alarms - Assign up to four relays plus warning on current loop, to inform the facility of gas monitor status and target gas value, delivering the highest system integrity.

   

Datasheets & Manuals
SensAlert Plus Datasheet (PDF)
FM Approvals Release - SensAlert Plus Ammonia Sensor (PDF) NEW!
SensAlert Plus Test-On-Demand (PDF)
SensAlert Plus User Manual (PDF)
SensAlert Plus Installation Options (PDF)
SensAlert Plus Remote Sensor (PDF)
SensAlert Plus Options & Accessories (PDF)

Sensor Datasheets - Please contact factory for complete list.
Ammonia - NH3 100ppm (PDF)
Ammonia - NH3 50ppm (PDF)
Ammonia - NH3 300ppm (PDF)
Ammonia - NH3 500ppm (PDF)
Carbon Dioxide - CO2 (IR) (PDF)
Carbon Monoxide - CO 100ppm (PDF)
Carbon Monoxide - CO 500ppm (PDF)
Chlorine - Cl2 10ppm (PDF)
Chlorine - Cl2 5ppm (PDF)
Chlorine - Cl2 20ppm (PDF)
Chlorine Dioxide - ClO2 1ppm (PDF)
Chlorine Dioxide - ClO2 5ppm (PDF)
Combustible Gas - Cat Bead (H2 Compatible) (PDF)
Combustible Gas - Cat Bead (PDF)
Combustible Gas - Infrared (PDF)
Ethylene Oxide - EtO 10ppm (PDF)
Hydrogen Chloride - HCl 10ppm (PDF)
Hydrogen Chloride - HCl 20ppm (PDF)
Hydrogen Cyanide - HCN 20ppm (PDF)
Hydrogen Flouride - HF 10ppm (PDF)
Hydrogen Flouride - HF 20ppm (PDF)
Hydrogen Sulfide - H2S 100ppm (PDF)
Hydrogen Sulfide - H2S 50ppm (PDF)
Hydrogen - H2 1000ppm (PDF)
Hydrogen - H2 100% LEL (PDF)
Nitrogen Dioxide - NO2 10ppm (PDF)
Oxygen - O2 % vol. (PDF)
Phosgene - COCL2 1ppm (PDF)
Sulfur Dioxide - SO2 10ppm (PDF)
Sulfur Dioxide - SO2 20ppm (PDF)