Gilian Air Sampling Pump Specifications
Gilian Air Sampling Pump Specifications and Part Numbers
Gilian Personal Pump Specifications
Gilian 3500 |
Gilian 5000 |
GilAir-3 |
GilAir-5 |
LFS-113 |
BDX-II |
|||||||
Total Flow Range |
20-3,500 cc/min |
20-5,000 cc/min |
1 - 3,000 cc/min |
1 - 5,000 cc/min |
1 - 350 cc/min |
500 – 3,000 cc/min |
||||||
High Flow Range |
700-3,500 cc/min0.7-3.5LPM |
800-5000 cc/min0.8-5LPM |
750-3,000 cc/min0.75-3.0 LPM |
750-5,000 cc/min0.75-5.0 LPM |
1-350 cc/min0.001-0.35 LPM |
500 – 3,000 cc/min0.5-3.0 LPM |
||||||
Low Flow Range, Constant Flow |
NA |
NA |
20-500 cc/min, to 25" H2O* (6.2 kPa) |
20-500 cc/min, to 25"
|
20-200 cc/min, to 25"
|
NA |
||||||
Low Flow Range,Constant Pressure |
20-750 cc/min, @15" ± 1.5" H2O*(3.7 ± 0.4 kPa) |
20-800 cc/min, @15" ± 1.5" H2O*(3.7 ± 0.4 kPa) |
1-750 cc/min, @15" ± 1.5" H2O*(3.7 ± 0.4 kPa) |
1-750 cc/min, @15" ± 1.5" H2O*(3.7 ± 0.4 kPa) |
1-350 cc/min, @15" ± 1.5" H2O*(3.7 ± 0.4 kPa) |
NA |
||||||
Max. Pressure Capability: |
Fault † |
8 hr. Run†† |
Fault † |
8 hr. Run†† |
Fault † |
8 hr. Run†† |
Fault† |
8-hr Run†† |
Fault |
†8 hr. Run†† |
Fault† |
8 hr. Run†† |
@ 0.35 LPM, Inches H2O
|
— |
— |
— |
— |
— |
— |
— |
— |
25
|
— |
— |
— |
@ 0.75 LPM, Inches H2O
|
45 (11.2) |
40 (10.0) |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
@ 1 LPM, Inches H2O
|
35 (8.2) |
30 (7.5) |
70 (17.5) |
70 (17.5) |
30 (7.5) |
25 (6.2) |
37 (9.2) |
29 (7.2) |
— |
— |
— |
— |
@ 2 LPM, Inches H2O
|
35 (8.2) |
30 (7.5) |
60 (15.0) |
60 (15.0) |
20 (5.0) |
15 (3.7) |
37 (9.2) |
26 (6.5) |
— |
— |
— |
— |
@ 2.5 LPM, Inches H2O
|
30 (7.5) |
25 (6.2) |
50 (12.5) |
50 (12.5) |
20 (5.0) |
15 (3.7) |
32 (8.0) |
23 (5.7) |
— |
— |
— |
20 (5.0) |
@ 3 LPM, Inches H2O
|
25 (6.2) |
20 (5.0) |
50 (12.5) |
50 (12.5) |
10 (2.5) |
8 (2.0) |
32 (8.0) |
23 (5.7) |
— |
— |
— |
— |
@ 3.5 LPM, Inches H2O
|
15 (3.7) |
12 (3.0) |
30 (7.5) |
30 (7.5) |
— |
— |
20 (5.0) |
18 (4.5) |
— |
— |
— |
— |
@ 4 LPM, Inches H2O
|
— |
— |
30 (7.5) |
30 (7.5) |
— |
— |
20 (5.0) |
18 (4.5) |
— |
— |
— |
— |
@ 5 LPM, Inches H2O
|
— |
— |
24 (6.0) |
20 (5.0) |
— |
— |
10 (2.5) |
8 (2.0) |
— |
— |
— |
— |
Data Shown In Display |
Live Flow Rate,Total Sample Time,Total Volume Sampled,Low Battery |
Live Flow Rate,Total Sample Time,Total Volume Sampled,Low Battery |
Elapsed Time(clock & timermodels),Low Battery,Flow Fault |
Elapsed Time(clock & timermodels),Low Battery,Flow Fault |
Elapsed Time |
NA |
||||||
Overall Dimensions:inchescentimeters |
|
|
|
|
|
|
||||||
Total Pump Weight |
19.5 oz. (0.53 kg) |
20.5 oz. (0.58 kg) |
21.0 oz. (0.6 kg) |
22.5 oz. (0.64 kg) |
12 oz. (0.34 kg) |
21 oz. (0.6 kg) |
||||||
Rechargeable Battery |
4.8v, NiMH |
7.2v, NiMH |
4.8v, NiCd (UL)
|
6.0v, NiCd (UL)
|
4.8v, NiCd (UL)
|
4.8v, NiCd (UL)
|
||||||
Operating Temperature |
32°F to113°F0°C to 45°C |
32°F to113°F0°C to 45°C |
32°F to113°F0°C to 45°C |
32°F to113°F0°C to 45°C |
32°F to 113°F0°C to 45°C |
32°F to 113°F0°C to 45°C |
||||||
Certifications*** |
UL, cUL, CE/ATEX |
FM, CE/ATEX, FMC |
UL and CE/ATEX Models |
UL and CE/ATEX Models |
UL and CSA,CE/ATEX Models |
UL |
||||||
Charging Time |
< 5 hours |
< 4 hours |
14-16 hours |
14-16 hours |
14-16 hours |
14-16 hours |
||||||
Battery Life ** |
300-500charge-recharge cycles, OR 2.5 years with <20 hours weekly use, 1.5-2.5 years (20-39 hours weekly use),
|
|||||||||||
* Requires installation of low flow module. † Typical back-pressure limit before fault with fully charged battery pack.
** Battery Life estimates based on proper battery maintenance. †† Maximum back-pressure for 8-hour run without fault.
*** Consult individual specification sheets as approvals can vary based on model
Gilian Pumps, Kits and Accessory Part Numbers
Gilian 3500 |
Gilian 5000 |
GilAir-3 |
GilAir-5 |
LFS-113 |
BDX-II |
|
Basic Pump, no Clock |
NA |
NA |
Model GilAir-3R |
Model GilAir-5R |
Model LFS-113DS |
Model BDX II |
800485-111 |
800883-111 |
800088-101 |
801863 |
|||
Pump With Clock |
810-0001-02 |
NA |
Model GilAir-3RC |
Model GilAir-5RC |
Model LFS-113DCS |
N/A |
800508-111 |
800885-111 |
800098-101 |
||||
Pump with |
NA |
810-0801-01 |
Model GilAir-3RP |
Model GilAir-5RP |
NA |
NA |
Programmable Timer |
800510-111 |
800884-111 |
||||
ATEX Pump Basic, No Clock |
NA |
NA |
Model GilAir-3S |
Model GilAir-5S |
Model LFS-113D |
NA |
810-0201-02 |
810-0101-02 |
810-0301-02 |
||||
ATEX Pump With Clock |
810-0001-02 |
NA |
Model GilAir-3SC |
Model GilAir-5SC |
Model LFS-113DC |
NA |
810-0202-02 |
810-0101-02 |
810-0302-02 |
||||
ATEX Pump with |
NA |
810-0801-01 |
Model GilAir-3SP |
Model GilAir-5SP |
NA |
NA |
Programmable Timer |
810-0203-02 |
810-0103-02 |
||||
Starter Kit, Pump w/ no Clock |
Model GilAir-3R |
Model GilAir-5R |
Model LFS-113DS |
Model BDX II |
||
- w/ 120V charger |
NA |
NA |
800485-111-1201 |
800883-111-1201 |
800088-101-1201 |
801863-120 |
- w/ 230V charger |
NA |
NA |
800485-111-2301 |
800883-111-2301 |
800088-101-2301 |
801863-230 |
- ATEX, w/ 230V charger |
NA |
NA |
910-0201-02 |
910-0101-02 |
910-0301-02 |
NA |
Starter Kit, Pump w/ Clock |
Model GilAir-3RC |
Model GilAir-5RC |
Model LFS-113DCS |
|||
- w/ 120V charger |
801934-1201 |
NA |
800508-111-1201 |
800885-111-1201 |
800098-101-1201 |
NA |
- w/ 230V charger |
NA |
NA |
800508-111-2301 |
800885-111-2301 |
800098-101-2301 |
NA |
- ATEX, w/ 230V charger |
910-0001-02 |
NA |
910-0204-02 |
910-0104-02 |
910-0303-02 |
NA |
Starter Kit, Programmable Pump |
Model GilAir-3RP |
Model GilAir-5RP |
||||
- w/ 120V charger |
NA |
910-0802-01 |
800510-111-1201 |
800884-111-1201 |
NA |
NA |
- w/ 230V charger |
NA |
NA |
800510-111-2301 |
800884-111-2301 |
NA |
NA |
- ATEX w/ 230V charger |
NA |
910-0802-02 |
910-0207-02 |
910-0107-02 |
NA |
NA |
Five-Pack Kit, Pump w/ no Clock |
Model GilAir-3R |
Model GilAir-5R |
Model LFS-113DS |
|||
- w/ BMS II Maint. System, US plug |
NA |
NA |
800485-111-B2 |
800883-111-B2 |
NA |
NA |
- w/ 120V Universal charger |
NA |
NA |
800485-111-1205 |
800883-111-1205 |
800088-101-1205 |
NA |
- w/ BMS II Maint. System, Euro plug |
NA |
NA |
NA |
NA |
NA |
NA |
- w/ 230V Universal charger |
NA |
NA |
800485-111-2305 |
800883-111-2305 |
800088-101-2305 |
NA |
- ATEX pump, w/230V univ. charger |
NA |
NA |
910-0202-02 |
910-0102-02 |
910-0302-02 |
NA |
- ATEX pump, BMS-II, Euro plug |
NA |
NA |
NA |
NA |
NA |
NA |
Five-Pack Kit, Pump w/ Clock |
Model GilAir-3RC |
Model GilAir-5RC |
Model LFS-113DCS |
|||
- w/ BMS II Maint. System, US plug |
NA |
NA |
800508-111-B2 |
800885-111-B2 |
NA |
NA |
- w/ 120V Universal charger |
910-0002-01 |
NA |
800508-111-1205 |
800885-111-1205 |
800098-101-1205 |
NA |
- w/ BMS II Maint. System, Euro plug |
NA |
NA |
NA |
NA |
NA |
NA |
- w/ 230V Universal charger |
NA |
NA |
800508-111-2305 |
800885-111-2305 |
800098-101-2305 |
NA |
- ATEX pump, w/230V univ. charger |
910-0002-04 |
NA |
910-0205-02 |
910-0105-02 |
910-0304-02 |
NA |
- ATEX pump, BMS-II, Euro plug |
NA |
NA |
NA |
NA |
NA |
NA |
Five-Pack Kit, Programmable Pump |
Model GilAir-3RP |
Model GilAir-5RP |
||||
- w/ BMS II Maint. System, US plug |
NA |
NA |
800510-111-B2 |
800884-111-B2 |
NA |
NA |
- w/ 120V Universal charger |
NA |
910-0801-01 |
800510-111-1205 |
800884-111-1205 |
NA |
NA |
- w/ BMS II Maint. System, Euro plug |
NA |
NA |
NA |
NA |
NA |
NA |
- w/ 230V Universal charger |
NA |
NA |
800510-111-2305 |
800884-111-2305 |
NA |
NA |
- ATEX pump, w/230V univ. charger |
NA |
910-0801-02 |
910-0208-02 |
910-0108-02 |
NA |
NA |
- ATEX pump, BMS-II, Euro plug |
NA |
NA |
NA |
NA |
NA |
NA |
Constant Low Flow Module |
NA |
NA |
800518 |
800518 |
NA |
NA |
Const. Pressure Multi-flow Module |
801961 |
801961 |
800519 |
800519 |
NA |
NA |
Battery Pack - Standard |
801930 |
783-0007-01 |
800464 |
800869 |
800086 |
801862 |
- RFI - Black |
800464-1 |
800869-1 |
NA |
NA |
||
- ATEX |
801930 |
783-0007-01 |
783-0008-01 |
783-0009-01 |
783-0003-01 |
NA |
Single-Station Charger
|
811-0802-01 |
811-0802-01 |
298-0006-01 |
298-0006-01 |
298-0005-01 |
298-0006-01 |
- for ATEX Batteries (230V) |
811-0802-02 |
811-0802-02 |
401097-1 |
401225-1 |
400198-1 |
NA |
Five-Station Charger
|
|
|
|
|
|
|
- 230V |
811-0801-02 |
811-0801-02 |
850070 |
850070 |
400373 |
850070 |
BMS-II 5-Station Battery |
||||||
Maintenance System
|
|
|
|
|
|
|
- 230V, for ATEX NiCd Batt., Euro plug |
NA |
NA |
850089-1 |
850089-1 |
NA |
NA |
- 230V, for non-ATEX NiCd Batt., Euro plug |
NA |
NA |
850086-1 |
850086-1 |
NA |
NA |
Single Sorbent Tube Holder Kit |
||||||
(no manifold; 6x70mm) |
800149 |
800149 |
800149 |
800149 |
800149 |
NA |
Dual Variable Manifold Sorbent |
||||||
Tube Holder Kit 6x70mm |
800148 |
800148 |
800148 |
800148 |
800148 |
NA |
7 - 10x110mm |
801407 |
801407 |
801407 |
801407 |
801407 |
NA |
Deluxe Variable Manifold Kit (all sizes) |
800232 |
800232 |
800232 |
800232 |
800232 |
NA |
Filter Cassette Holder Kit |
800143 |
800143 |
800143 |
800143 |
800143 |
800143 |
Related Links
- NIOSH Methods
- Gilian Air Sampling Pumps
- Air Sampling Accessories and Media
- Calibration Equipment
Shop Online