Sensidyne Industrial Health and Safety

GilAir Plus Personal Air Sampling Pump (1 - 5,100 cc/min)

Celebrating 10+ Years as our MVP - The Industry's Most Versatile Pump.
Trusted by IH Professionals Around The Globe.

GilAir Plus Personal Air Sampling Pump (1 - 5,100 cc/min)

One Air Sampling Pump with All the Features You Need and Want

 3 Prime Updated Technologies

  • Motion Detection
  • Bluetooth Connectivity
  • Gilian CONNECT Mobile App

 Also Features:

  • QuadModeSM Air Sampling Technology
  • Selectable Automatic Fault Recovery
  • Standard Temperature & Pressure (STP) Correction
  • Superior Design & Comfort
  • Real-time Clock with Data-logging

 

Read Our Report on "Air Sampling for COVID-19," including solutions with the GilAir Plus

 

Motion Detection

Detect and measure up to 3 levels of activity (active, stationary, inactive) of each worker, ensuring sample integrity

Bluetooth Connectivity

  • Remotely monitor an air sampling pump up to 5 meters (16.4 ft.) away
  • No disturbance of the worker
  • Stay in unrestricted areas while workers are in restricted areas 
  • No need to suit up

CONNECT Mobile App

  • Apple Mobile App Compatibility:
    • iPod Touch, iPhone, and iPad
    • iOS 10 through iOS 13
    • 64 bit
  • Android Mobile App Compatibility:
    • OS Version: 6 or higher
    • 64 bit
    • Bluetooth 4.0 or higher
       
  • Start, stop or pause the sample remotely
  • Monitor and graph flow rate, sample run time, and volume remotely
  • Perform real-time remote assessments:
    • Identify if cassette is overloading
    • Identify if filter media is detached
  • Sample audits provide the following on a smart phone or tablet:
    • Report of current conditions
    • Screen shot of current conditions
    • Time stamp
    • GPS coordinates (actual address)
    • Pump number
    • E-mailable report
  • Check the status of multiple pumps in the same area

=> Go to Gilian CONNECT tab to download PC software

Please contact Sensidyne’s Software Support Team at [email protected] with questions regarding additional devices or support for this application.
 

Innovation Delivered:  The ultimate personal air sampling pump delivering enhanced performance, greater versatility, and superior design and comfort.

The Widest Flow Range of Any Personal Air Sampling Pump

Personal Industrial Hygiene Air Sampling PumpThe GilAir® Plus features wide dynamic flow and pressure ranges to address all personal air sampling methods with flow ranges between 20 and 5,100 cc/min. With patent pending QuadModeSM air sampling technology, the GilAir Plus can perform both high-flow constant pressure and constant flow (450-5,100 cc/min) and low-flow constant pressure and constant flow (20-499 cc/min) with a single pump without external adaptors. It's like getting two pumps in one.

 

Unmatched Versatility

  • Samples particulates, vapors, gases, and metal fumes
  • Works with all common sampling media
  • Multi-language capability: English, Spanish, French, Italian, Dutch, Portuguese and German
  • Outlet port for bag sampling

 

 

PC ApplicationHigh Performance

GilAir Plus is a smart air sampling pump that provides ambient or standard temperature and pressure corrected display (STP model) and data-logging for up to 16 sampling events (STP and Datalog model). The pump has high back pressure capability of up to 40" H2O in high flow and up to 40" H2O in low flow. An automatic self check system ensures sample accuracy. In the event of a fault condition, the pump's selectable automatic fault recovery feature attempts to restart the pump up to 10 times every 3 minutes to determine if the fault condition has been cleared.

 

Easy-to-read, backlit displays  air sampling pumpsEase of Use

An intuitive menu, keypad interface and large, easy-to-read back-lit display makes adjusting pump settings quick and easy. Once the pump is set up, the keypad can be locked to prevent tampering. Convenient and innovative SmartCalSM feature provides automatic pump calibration.

 

Compact Personal Air Sampling PumpErgonomic Design

One-third smaller than traditional personal air sampling pumps and weighing less than 21 oz. (595 g), the GilAir Plus provides superior operator comfort. An integrated belt clip securely attaches the pump in a horizontal position, allowing workers a full range of motion to perform a wide variety of tasks without interference or discomfort.

 

Communications

Multi-pump DocksThe GilAir Plus dock provides charging and communication functions for the STP and data-logging models. Once docked, the PC application allows users to review datalogs, generate sampling reports, manage sampling programs, and create pump set-up profiles that expedite deployment of large pump fleets. The SmartCalSM feature uses the dock as a communication link between appropriate calibration devices and the GilAir Plus. SmartCalSM automates calibration and records pre and post sample calibrations in the pump's datalog.

Gilian CONNECT is our industry-leading PC application for managing air sampling data and Gilian Plus Series pumps.

Click to learn more about Gilian CONNECT

 

Barometric Pressure Compensation

When sampling at altitudes of up to 8,000 feet above or 8,000 feet below sea level, GilAir Plus has the capability of automatically correcting the flow rate for altitude changes to maintain constant flow accuracy of +/- 5% over this barometric pressure range. This feature permits GilAir Plus calibration at ground level and sampling at high elevations or deep mines without loss of flow accuracy or the need to calculate and use manual correction factors. GilAir Plus is the only personal air sampling pump with this capability.

Download the Barometric Pressure Sampling Note

Turbo-charge the productivity of your Gilian equipment: 
Go beyond just data collection!

   

Streamline workflows, boost efficiency, and gain deeper insights with the all-new Gilian CONNECT Pro software. Minimize time-consuming tasks and cumbersome processes.

Gilian’s new PC application elevates everything about Gilian CONNECT to the next level, empowering you to manage your air sampling operations with ease and control.

Gilian CONNECT Pro is more than just streamlined data management.
It’s about unlocking the full potential of your Gilian air sampling and calibration instruments with powerful new features and benefits:

  • Advanced configuration and programming tools — saves time and resources.

  • Enhanced reporting capabilities with improved data visualization tools — allows users to gain deeper insights and make informed decisions.

  • Integrates and links information — from GilAir Plus air sampling pumps and Go-Cal Pro air flow calibrators for complete air sampling continuity.

  • Download and organize — easy filtering allows review of historic events where exposure limits have been exceeded.

  • Customize the software — to your specific needs, including user preferences, measurement units,
    and reporting templates.

Gilian CONNECT Pro seamlessly integrates with:

Gilian CONNECT Pro is PC compatible with Microsoft Windows OS 10 or higher.

Current CONNECT Pro Version 1.0.0.3 is compatible with:

  •  GilAir Plus pumps with Firmware 2.4.0 and higher, released in July of 2015
  •  GilAir Plus Docking Station with Firmware 3.3 and higher, released in December of 2016
  •  All recently launched Go-Cal Pro calibrators with Firmware 1.0.4 and higher 

Download the software installation file:

1. Download the .zip file, double-click to extract the .exe file
2. Double-click the .exe file to install Connect Pro

DOWNLOAD .exe Zip FILE

Download a PDF of the Datasheet:

DOWNLOAD DATASHEET

Download a PDF of the Manual:

DOWNLOAD MANUAL

 

 

Click to Learn about the Gilian CONNECT Mobile App:

CONNECT MOBILE APP

 

Support

If you would like any assistance downloading, installing, or using Gilian CONNECT Pro, please click to Email to: Sensidyne Software Support

NEW!  Gilian GilAir Plus Features & Benefits Overview

 

NEW!  How to Calibrate a High-Flow Split Manifold
=> For media on a GilAir Plus pump, using a Go-Cal Pro calibrator

 

 

 

 

 

Click on a file below to open. Visit our Technical Library for further documents and resources.

Filename Filesize
1_GilAir Plus Operation Manual_Software Version 2 5 4_360-0132-01rAC.pdf 3.61 MB
2_Gilian_GilAir-Plus_Datasheet-2021_rH.pdf 1.05 MB
Dual Port High Low Flow Manifold 360-0154-01rC.pdf 224.12 kB
GilAir-Plus_Barometric-Altitude-Sampling.pdf 431.58 kB
GilAir-Plus_QuadMode-High-Flow-Article.pdf 1.12 MB
GilAir Plus-Battery Charging Instruction Sheet 360-0184-01rA.pdf 135.75 kB
GilAir Plus Belt Clip Instructions.pdf 197.97 kB
GilAir Plus Hose Kit Instructions 360-0209-01rB.pdf 205.92 kB
GilAirPlus PC Application Manual Software Version 1.3.0 360-0143-01rF .pdf 1.6 MB
GilAir Plus Quick-Start Guide DUTCH 360-0135-04rE.pdf 844.32 kB
GilAir Plus Quick-Start Guide ENGLISH360-0135-01rE.pdf 961.1 kB
GilAir Plus Quick-Start Guide FRENCH 360-0135-06rE.pdf 916.51 kB
GilAir Plus Quick-Start Guide GERMAN 360-0135-02rE.pdf 927.78 kB
GilAir Plus Quick-Start Guide ITALIAN 360-0135-08rE.pdf 958.55 kB
GilAir Plus Quick-Start Guide PORTUGUESE 360-0135-10rE.pdf 964.51 kB
GilAir Plus Quick-Start Guide SPANISH 360-0135-11rE.pdf 979.03 kB
GilAir Plus Quick-Start Guide TURKISH 360-0135-14rC.pdf 984.29 kB
GilAir Plus Tri-Pod Mount Instruction Manual 360-0198-01rB.pdf 414.3 kB
GilAir Plus_Connect Mobile and Bluetooth_QuickStart Guide (V4)_rB.pdf 2.41 MB
Gilian Connect Software_CD download_02-21.pdf 175.9 kB
Gilian Connect Software_Quick Start Guide 360-0176-01rD.pdf 1.57 MB
Gilian Connect Software_summ.pdf 320.59 kB
Gilian_Dual-Port_High-Low_Flow_Manifold.pdf 527.14 kB
Gilian_GilAir-Plus_Battery Recommendations.pdf 882.08 kB
Gilian_GilAir-Plus_Personal-Pump-Pouch.pdf 891.44 kB
Gilian_GilAir-Plus_Run-Time-Performance.pdf 447.85 kB
Instruction-Impinger Mounting_3_.pdf 204.84 kB

PRODUCT SPECIFICATIONS

Performance

Firmware

Current Version: 2.5.4 (6/20/17)

 

Flow Range

Constant flow 20 - 5,000 cc/min. without external adaptors

Constant pressure 1 - 5,000 cc/min without external adaptors

 

Flow Modes

Constant Flow or High and Low Flow Constant Pressure

 

Accuracy

Flow Display ± 5% or 3 cc/min of set flow, whichever is larger

Constant Flow Control ± 5% or 3 cc/min of set flow, whichever is larger

Constant Pressure Control ± 10% of back-pressure

 

Back Pressure Capability

(8-hour runtime) 5000 cc/min. up to 12” H20 back pressure 

4000 cc/min. up to 20” H20 back pressure

3000 cc/min. up to 30” H20 back pressure

2000 cc/min. up to 30” H20 back pressure

1000 cc/min. up to 35” H20 back pressure

450 - 1000 cc/min. up to 40” H20 back pressure

20 - 449 cc/min. up to 40” H20 back pressure

Run Time 8 hour minimum

Flow Fault If flow changes exceed 5% within back pressure specifications, fault notification appears. If fault exceeds 30 seconds, pump shuts down. Selectable automatic fault recovery allows the pump to attempt restart every 3 minutes for up to 10 times or to hold until manual intervention.

 

Environmental

Temperature Ranges

Operating 32°F to 113°F (0°C to 45°C)

Storage -4°F to 113°F (-20°C to 45°C)

Charging 41°F to 104°F (5°C to 40°C)

 

Humidity Ranges

Operating 5-95 %RH, non-condensing

Storage 5-98 %RH, non-condensing

 

GENERAL

Display Flow rate, sample time, and sample volume in actual conditions

 

Controls

Indicators Green and Red LED’s

Dimensions 4.3 x 2.4 x 2.4 inches (10.9 x 6.1 x 6.1 centimeters)

Weight 20.5 ounce (581 grams)

Warranty 2 years from original shipment, 5 years for pump keypad, and 1 year on rechargeable NiMH battery pack

 

ELECTRICAL

Power Options Removable rechargeable nickel-metal hydride (NiMH) battery pack, optional alkaline battery pack, or DC power

Battery Level Indicator On-screen icon displays battery level

Interface Connectors All pump interface is carried out via the Dock or keypad

Dock Functions Battery charging, computer interface, and auto-calibration

Charging Time Under 3.5 hours

 

APPROVALS

ISO 13137:2013 Compliant

Intrinsic Safety

US/Canada NRTL (FM) Class I, Div 1 Groups A, B, C, D, E, F, and G;

Class II, Div 1 Zone 0; Class III, T4

ATEX/IECEx

​II 1 G

Ex ia IIC T4 

CE

Applicable Directives ATEX 94/9/EC

EMC 2004/108/EC (RFI) LVD 2006/95/EC

RoHS Compliant